Author:
Bulanov V A,Zakharov A V,Khivintseva E V
Abstract
Abstract
The reliability of a newly developed algorithm for the identification of the P300 component of event-related potentials based on a continuous wavelet transform was investigated. The electroencephalogram records of one participant made by using a three-stimulus paradigm (a kind of the odd-ball paradigm) were analyzed. The accuracy of identification of certain wavelet types for the detection of P300 was from 76.32 to 86.84%. Thus, relatively simple algorithms for processing and classifying the electroencephalogram record signal show acceptable results in terms of the accuracy of identification of the P300 component of event-related potentials based on randomly selected data.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献