Author:
Arkhipov V E,Moskvitin G V,Pugachev M S
Abstract
Abstract
The paper studies the effect of the structure of copper and brass coatings, obtained by gas-dynamic spattering, on their tribological behaviour. Using durometrical, chemical and X-ray analyses, as well as the wear tests, the authors have determined that the copper coating structure hardness is 102.7 HV, it has pores up to 2 urn in diameter, brass coating consists of 106.5 HV copper, 49.7 HV zinc and 168.7 HV non-metallic compositions (y - and e - phases), distributed by mass as 62:7.9:24.2 % correspondingly. The both coatings have presented good results in sliding friction couple tests.