Abstract Background: Monitoring patients radiation dose during anterior-posterior (AP) pelvis radiography is of paramount importance. This is due to the existence of the gonads within the pelvic region. Objective: The purpose of this work is to estimate effective dose (ED) for adult patients who examined for AP pelvis radiography in the governmental hospitals of Al Najaf city-Iraq. Materials and methods: The ED was estimated for 64 patients (male and female) who undertaking AP pelvis radiography using CALDOSE-X5 Monte Carlo software. The calculation of the ED was based on the measurements of X-ray tube output and the knowledge of exposure factors. The X- ray output was measured using Rad-Check ionization chamber for each X-ray tube. In total, seven X-ray tubes were enrolled to assess the patients’ ED. Exposure factors includes tube potential (kVp), tube loading (mAs) and X-ray source to image detector distance-SID (cm)); these were recorded for each patient together with their demographic data (weight(kg) and height(m)). Five major hospitals were considered in this work (i.e. Al Sadder, Al Hakeem, Al Furat, Al Manzrah and Middel Euphrates cancer center). Results: The average value of the estimated ED was ranged from 0.156±0.041 mSv to 0.4068±0.049 mSv across all hospitals. The value of max/min of the ED was ranged from 1.25 to 2.58 across different hospitals. The corresponding average values of the kVp used for this examination was ranged from 75 to 113.75 kVp; mAs: ranged from 11.7 to 42.1 mAs and for the SID the range was between 100 and 140.6 cm. Conclusion: The resulted data demonstrate there is a clear variability in patient dose and exposure factors set among the selected hospitals. The ED values were seen to be slightly lower than those reported by the UK (Survey-2010, 0.284 mSv) and were higher than those reported by certain countries (e.g. Canada, Ghana etc.). Overall, a periodic checking together with conducting a quality control testing is highly recommended.

Publisher

IOP Publishing

Subject

General Medicine

Reference29 articles.

1. Excess cancer risk assessment from some common X-Ray examinations in Sabzevar County;Bahreyni Toossi;Iranian Journal of Medical Physics,2011

2. Mori M. Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters;Kawaura;Radiation protection dosimetry,2006

3. Linton OW. NCRP report No. 160, ionizing radiation exposure of the population of the United States, medical exposure—are we doing less with more, and is there a role for health physicists?;Schauer;Health physics,2009

4. Evaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran;Zarghani;Iranian Journal of Medical Physics,2015

5. The importance of radiation quality for optimisation in radiology;Martin;Biomedical imaging and intervention journal,2007

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3