Author:
Kashan Jenan S.,Ali Saad M.
Abstract
Abstract
High-density polyethylene (HDPE) matrices reinforced with titanium dioxide (TiO2) biocomposites are seen as promising biomaterials due to their superior properties. In this work, an attempt was made to study the effects of six biocomposites hybrid Titanium dioxide (TiO2) and yttria-stabilized zirconia (Y-PSZ) samples reinforced with high-density polyethylene (HDPE) matrices, split into two groups, in terms of withstanding the daily activity loads imposed by human bone grafting and repairs. The fabricated composites were investigated using the hot-pressing technique at different compression pressures and compounding temperature. To achieve characterization, thermal analysis of the process using differential scanning calorimetry (DSC) techniques was undertaken. To improve and verify the results, Design Expert 11.0 software and a response surface methodology (RSM) technique were used. For both nanofabricated types, the results showed that an increase in TiO2 ceramic filler from 1% to 10 %, caused percentage crystallization to increase by 14.58%. The heat of system fusion for the second fabricated system also decreased by 11%. These results show that this addition reduced the heat of system fusion by 109% compared with previous studies. The glass transition (onset) and end (melting) temperature also increased with increases in the applied compression pressure and hot-pressing temperature when a small value, 1%, of TiO2 ceramic nanoparticle fillers in the HDPE matrix. The temperature values were increased when using higher compression pressure of between 60 and 90 MPa, and the onset temperature reached a maximum value of 127 °C. This increase in onset temperature continued when using higher values of TiO2 Nanoceramic filler and the onset temperature reached its maximum value with 10% TiO2 and 2% PSZ Nanoceramic fillers added to the fabricated nanomaterial system. The differential scanning calorimetry (DSC) scanned curves and the 3D atomic force microscopy (AFM) microstructure and granularity distribution images for both fabricated nanocomposite systems clearly showed that the interconnections between the filler’s ceramic nanoparticles within the polymeric matrix offer high surface roughness values due to the excellent nanofiller particle distribution within the polymeric matrix.
Reference29 articles.
1. A numerical comparative analysis of ChM and Fixion nails for diaphyseal femur fractures;Dmitry;Acta of Bioengineering and Biomechanics,2016
2. Numerical Analysis of Fractured Femur Bone with Prosthetic Bone Plates;Senthil;Procedia Engineering,2013
3. Numerical modeling of an osteoporotic femur: comparison before and after total hip prosthesis implantation;Mohamed;European Journal of Computational Mechanics,2008
4. Numerical Simulation of The Femur Fracture with and Without Prosthesis Under Static Loading Using Extended Finite Element Method (X-FEM);Zagane;Journal of Mechanical Engineering,2017
5. Finite element analysis of human fractured femur bone implantation with PMMA thermoplastic prosthetic plate;Ajay;Procedia Engineering,2019
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Design and Fabrication of a Low-Cost Actuated Hand Orthosis for Rehabilitating Paralyzed Patients;2022 2nd International Conference on Advances in Engineering Science and Technology (AEST);2022-10-24