Author:
Ding Zhaochen,Dong Jingshi,Yin Haojie,Wang Zhe,Zhou Xiaoqin,Xu Zhi
Abstract
Abstract
In order to reduce the regression phenomenon of the piezoelectric stick-slip actuator, and improve the output performance, a piezoelectric stick-slip actuator with regular octagonal flexible hinge mechanism is proposed in this paper. The pseudo-rigid body method is used to analyze the regular octagonal flexible hinge mechanism and the flexible driving foot respectively.A prototype is fabricated to test the working performance and the results demonstrate that the minimum step is 0.01μm, the maximum speed is 145251μrad/s, and the maximum load carrying capacity is 500g. The experimental results show that the parasitic motion suppresses the regression of the actuator and improves the output stability.
Reference12 articles.
1. Piezoelectric circular diaphragm with mechanically induced pre-stress for energy harvesting;Palosaari;Smart Mater. Struct.,2014
2. Piezoelectric Insulin Pump[J];Jingshi;Journal of Xi’an Jiaotong University,2007
3. Note: A novel rotary actuator driven by only one piezoelectric actuator[J];Huang;Review of Scientific Instruments,2013
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献