The effect of different α and β gable on stainless steel and TMA segmental T-loop on the resulting force – an in vitro study

Author:

Laviana A

Abstract

Abstract Adding more angle to the segmental T-Loop gable can affect the amount of force created to retract the canine on an orthodontic treatment with extraction. In-vitro laboratory experimental design, performed at the Chemistry Laboratory of Faculty of Science, ITB. The samples are 60 segmental T-loop springs with α and β angle of 0°–0°; 0°–45°; 45°–0°; 22.5°–22.5°; 15°–30°; 30°–15°. Force was measured using autograph with retraction distance of 1, 2, and 3 mm, then analyzed using ANOVA statistics analysis with a factorial design of 2x3x6 and 5 replications for each cell. The results of the posthoc Student Newman Keuls and Tukey test show that the added angle to the α and β gables of SS and TMA T-loop will add more resulting force along with the increase of retraction distance. The added angle to the α and β gables of SS and TMA segmental T-loop will add more resulting force along with the increase of retraction distance. The force resulted by the SS T-loop with various α and β gables are significantly different, while the force resulted by the TMA T-loop are not (p-value <0.05), as long as α + β is the same. The force resulted by the SS T-loop with various α and β gables are significantly different. However, on the TMA segmental T-loop, as long as α + β is the same, the force resulted will not be different.

Publisher

IOP Publishing

Subject

General Medicine

Reference14 articles.

1. Laboratorial study of the cuspid’s retraction timing and tipping effects during space closure, using the segmented arch technique;Bisol;Dental Press J Orthod,2010

2. En masse retraction versus two step retraction of anterior teeth in extraction treatment of bimaxillary protrusion;Felemban;J Orthod Science,2013

3. Evaluation of tensile strength of different configuration of orthodontic retraction loops for obtaining optimized forces;Blaya;Stomatologija Baltic Dental and Maxillofacial Journal,2009

4. Temperature effects on the force, moments and moment to force ratio of nickel-titanium and TMA symmetrical T-loops;Lim;Angle Orthod,2008

5. Curvature versus V-bends in a group B titanium T-loop spring;Martins;Angle Orthod,2008

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献