Author:
Arjun K. B.,Harikeshava R.,Sreenath C. R.,Srihari G.,Vaira Vignesh R.,Padmanaban R.
Abstract
Abstract
Aluminum alloys are widely used in engineering applications. In motion established contact applications, wear is an inevitable phenomenon. In this study, the wear mechanism of AA5052was explored using pin-on-disc tribometer. The wear test parameters namely load (kg), sliding distance (m), and velocity (m/s) were varied according to central composite design. The wear tracks of the worn specimens were observed using high-resolution scanning electron microscope and the elemental composition was analysed using energy dispersive X-ray spectroscopy. A hybrid model integrating the linear function and radial basis function was developed to explore the effect of load, sliding distance, and sliding velocity on the wear rate of the AA5052 alloy. The results indicate that increase in axial load and sliding distance decreases the wear rate of the AA5052 alloy.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献