The paper considers the task of improving the reliability of standby diesel generator sets of nuclear power plants (NPP) of the Russian Federation. A solution to the problem using a portable software and hardware diagnostic complex (I&C complex) that provides registration, processing, analysis and storage of data is proposed. The article describes in detail the main provisions of the methodology to monitor the state of the object. A method of analyzing the state of a diesel generator unit (DGU) based on representing an array of vibration and ultrasound parameters in the space of the principal components is used. The results of I&C complex tests for the diagnostics of NPP DGU are presented. An assessment of the resource of equipment based on the results of diagnostics for risk management, improving equipment reliability and cost savings is proposed. Haчните свою аннотацию здесь…
Reference19 articles.
1. Mechanical Vibration. Machine Vibration Assessment from Measurements on Non-Rotating Parts. Part 5,2015
2. Parametrical Assessment of Damage for Diesel Fuel Injection Systems. Seminar on Diesel Fuel Injection System of Institution of Mechanical Engineers;Arques,1989
3. A Review of Process Fault Detection and Diagnosis. Part I: Quantitative Model-Based Methods;Venkatasubramanian;Computers and Chemical Engineering,2003