The FRIB cryogenic engineering group designed and built the sub-atmospheric cold box which supports the 2 K (31 mbar) operation of the FRIB accelerator cryo-modules. The centrifugal cryogenic (cold) compressors, designed with room temperature motors and active magnetic bearings, were supplied by Air Liquide to FRIB specifications and were integrated into the cold box which was built on site. The preliminary commissioning tests demonstrated that the system has achieved all the specification goals of operating from 110-180 g/s with a suction pressure of 0.028 mbar, discharge pressure of 1.15 bar and a discharge temperature less than 30 K. This paper will briefly review the sub-atmospheric 2 K system design features and discuss the recent commissioning results.
Reference9 articles.
1. Process options for nominal 2-K helium refrigeration system designs;Knudsen;AIP Conf. Proc.,2012
2. Specification of eight 2400 W at 1.8 K refrigeration units for the LHC;Claudet;CERN LHC Project Report,2000
3. Large cryogenic systems at 1.8 K;Tavian,2000
4. Large-scale 2-K cryoplant experience;Tavian,2012
5. Optimal design and operation of helium refrigeration systems using the Ganni cycle;Ganni;AIP Conf. Proc.,2010