Author:
Azis H A,Cholish ,Rimbawati ,Evalina N
Abstract
Abstract
In general Audio Amplifier using linear transformer-based power supply as energy conversion. Such use may cause interference with electrical installation sourced from the substation circuit. The non-linear load would cause problems in the electrical installation system. This research shows that Switch Mode Power Supply (SMPS) has a minimum voltage Vdrop output load of about 100 to 33.33 ohms. On the burden of 25-20 ohms as the voltage Vdrop output, which is different from Linear Power Supply Transformer-based parameters, that its voltage Vdrop output was changed significantly.
Reference10 articles.
1. High-Efficiency AC-DC Switch-Mode Power Supply Using Full-Bridge Converter Circuits;Su-Han;International Jurnal Of Control and Automation,2014
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献