Author:
Rahardjo I A,Djaohar M,Subekti M,Kamaruddin E
Abstract
Abstract
This study aims to mitigate harmonics in a Single Phase Inverter in the design of inverter products with harmonics filters which can later be used as a basis for consideration of the quality of electricity on the harmonics side for the use of AC load power with power plants sourced from DC generators using an inverter. An experimental electrical circuit was configured by giving nonlinear loads effect to determine the number of harmonics that appear. Then design filters on the circuit to mitigate the harmonics that occur in accordance with IEEE 1531-2003 standard. The greater the non-linear loads, the greater the voltage and current harmonics were produced. To mitigate the harmonic value due to non-linear loading with a tolerance of 5% to conform with IEEE 1531-2003 standards, a non-linear load of 60 W need to be fitted with a filter of an inductor 6.705594 Henry and a capacitor 1.50121990 Micro Farad in the inverter, a non-linear load of 104 W need to be fitted with a filter of an inductor 4.680568 Henry and a capacitor 2.15045863 Micro Farad in the inverter, a non-linear load of 146 W need to be fitted with a filter of an inductor 3.523966 Henry and a capacitor 2.85603348 Micro Farad in the inverter, a non-linear load of 187 W need to be fitted with a filter of an inductor 4.012541 Henry and a capacitor 2.50837720 Micro Farad in the inverter, a non-linear load of 230 W need to be fitted with a filter of an inductor 3.455178 Henry and a capacitor 2.91347361 Micro Farad in the inverter, a non-linear load of 268 W need to be fitted with a filter of an inductor 3.071107 Henry and a capacitor 3.27678662 Micro Farad in the inverter, a non-linear load of 311 W need to be fitted with a filter of an inductor 2.703245 Henry and a capacitor 3.72269662 Micro Farad in the inverter, a non-linear load of 351 W need to be fitted with a filter of an inductor 2.372288 Henry and a capacitor 24306264 Micro Farad in the inverter, a non-linear load of 390 W need to be fitted with a filter of an inductor 2.151711 Henry and a capacitor 4.67803044 Micro Farad in the inverter, a non-linear load of 429 W need to be fitted with a filter of an inductor 1.601979 Henry and a capacitor 6.28333291 Micro Farad in the inverter.
Reference11 articles.
1. Multi-input DC-AC Inverter for Hybrid Renewable Energy Power System;Rosli;Int. J. Electr. Comput. Eng.,2016
2. Design and Implementation of a Three Phase Inverter for Renewable Energy Source with Unified Control Strategy;Pillai;Energy Procedia,2016
3. A comprehensive study of classical and hybrid multilevel inverter topologies for renewable energy applications;Kala;Renew. Sustain. Energy Rev.,2017
4. Islanded operation of microgrids with inverter connected renewable energy resources;Pota;IFAC Proc. Vol.,2014
5. Effect of Non-Linear Electricity Loads Against Harmonics in One Phase Inverters;Rahardjo,2019
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献