Abstract
Large error exists in the photometric performance test of raised pavement marker. This paper reports a set of retroreflective measurement standard devices built to measure raised pavement markers based on the principle of direct measurement, and the photometric performance of the raised pavement markers was tested. The study also involved calibration of a portable meter using the standard device. According to the experimental comparison, the method proposed in this paper provides a new direction for the development of retroreflection measurement technology. The results measured by the proposed method showed high accuracy. This method can solve the large measurement error problems with indication errors of 2% at most.
Reference6 articles.
1. Design Improvements of Retroreflective Raised Pavement Markers Based on Quantification of Their Physical Properties[R];Lu,2016
2. Fused Raised Pavement Marker Detection Using 2D-Lidar and Mono Camera[C];Nguyen,2015
3. Measurement for Coefficient of Retroreflected Luminance by Direct Luminance Method[J];Zhao;Jiliang Xuebao/Acta Metrologica Sinica,2017
4. Corner-cube retroreflectors based on structure-assisted assembly for free-space optical communication[J];Zhou;Journal of Microelectromechanical Systems,2003