Abstract
The position deviation effect on force sensor with a resolution of micro newton scale was investigated by theory model analysis and numerical simulation method. The finite element method and theoretical model were used to analyse the influence of the electrostatic micro force sensors when the electrode position of the cylindrical capacitor changed. Relationship between the sensor output micro force and the position deviation of the internal electrode in the cylindrical capacitance was obtained. It was found that different position deviation form had different degrees of influence on the sensor’s output result and the regions with little effect by position deviation were existed. For translation along Z-axis, the region was [-4 mm, 14 mm]. For translation along r-axis, the region was [-0.2 mm, 0.2 mm]. And for rotation around r-axis, the region was [-1°, 1°]. The corresponding maximum errors of the micro force output were 1.49%, 2.09% and 2.20%, respectively.
Reference17 articles.
1. Overview of micro-force sensing methods[C];Ma;Applied Mechanics and Materials. Trans Tech Publications,2014
2. An overview of micro-force sensing techniques[J];Wei;Sensors and Actuators A: Physical,2015
3. Upconverting nanoparticles as optical sensors of nano to micro Newton forces[J];Lay;Nano letters,2017
4. High Precision Thrust Balance Development at The George Washington[C];Kolbeck,2017
5. Note: Precision balance for sub-miliNewton resolution direct thrust measurement[J];Karadag;Review of Scientific Instruments,2018
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献