Author:
Jasinski Radoslaw,Galman Iwona
Abstract
Abstract
The paper presents the results of experimental tests performed on six wall joints. The tests were performed on the models made of AAC blocks with thin joints and unfilled head joints. The joints were constructed as traditional masonry joints. The tests were performed in a dedicated test stand in which force was transferred linearly along the whole height of the wall. Specimens were loaded in one cycle until failure. The paper discusses the mode, morphology and mechanism of failure, and analyses the load–displacement relationships which allowed to define the phases of joint behaviour. By applying code procedures, authors provide the parameters required for the design of the joints. Using the values of cracking and failure forces obtained in experimental tests characteristic strengths at the moment of cracking and failure were determined. The obtained shear strengths were compared with the code values specified by Eurocode 6.
Reference12 articles.
1. Vermeiden von schädlichen Rissen in Mauerwerkbauteilen;Schubert;Mauerwerk-Kalender, Ernst & Sohn,1996
2. Comparison of two ways of AAC block masonry strengthening using CFRP strips-diagonal compression test;Kubica;Procedia Engineering,2017
3. Shear behaviour of masonry panels strengthened by FRP laminates;Valluzzi;Construction and Building Materials,2002
4. Problem of the crack formations in the area of intersecting loadbearing walls built with AAC masonry unit;Drobiec;Proceedings of the 5th International Conference on Autoclaved Aerated Concrete,2011
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献