Random vibration, exported vibration, and passive isolation testing of the Ricor K508N cryocooler

Author:

Anderson L,Mork J,Swenson C,Zwolinski B,Mastropietro A J,Sauder J,McKinley I,Mok M

Abstract

Abstract The Ricor K508N is a rotary Stirling Cryocooler whose predecessor, the K508, has extensive flight heritage. The K508N has significant potential as a low-cost option for CubeSat infrared electro-optical payload applications. This paper will explore the work done by the ATA project on the exported vibration characterization of a set of standard K508N cryocoolers (35 atm) and the implementation and performance comparison of several passive vibration isolation and damping technologies to help mitigate the jitter effect of COTS cryocoolers. Kistler Force dynamometers and accelerometers were used to measure the K508N’s body and cold tip Multicomponent Exported Forces and Torques (EFT). Wire rope and Pyrolytic Graphite Sheet thermal straps are used as vibration isolation technologies. The K508N also underwent sine sweep resonant and peak profile testing as well as random vibration testing to GEVS launch loads in a NanoRacks soft stow configuration.

Publisher

IOP Publishing

Subject

General Medicine

Reference9 articles.

1. CubeSat active thermal management in support of cooled electro-optical instrumentation for advanced atmospheric observing missions;Anderson;Proc. SPIE 10769, CubeSats and NanoSats for Remote Sensing II

2. Thermal and exported vibration characterization of RICOR K508N cryocooler;Mok;IOP Conference Series: Materials Science and Engineering,2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3