Performance Evaluation of the Single-Stage Absorption Cooling System through Energy and Exergy Analysis

Author:

Zaidan Maki H,Khalaf Hameed J,Hashim Abdulghafor M

Abstract

Abstract In this study, a single effect (H2O-LiBr) water lithium bromide absorption cooling system is presented and evaluated by energy and exergy analysis. A mathematical thermodynamic model of the absorption cooling system has been found and derived from the basic principles of the first and second laws of the thermodynamics. The important parameters of performance are focused on the coefficient of performance COP and exergy efficiency. The performance was carried out over a range of operating conditions including the effect of generator, absorber and ambient temperatures. An energy and exergy investigation of separate system components were also obtained. The main obvious effect is detected for the situation of exergy efficiency for generator and absorber. The exergy efficiency increases with the rise of absorption temperature and a reverse effect is detected when the temperature of generator increases. The performance comparison of system components has been conducted in the present study. Exergy destruction of the generator was noticed to be 42% higher than exergy destruction in the absorber of 28%, due to the mixing of lithium bromide and water at high generator temperature of about 88°C. The COP of the absorption refrigeration system differs at the range (0.6 - 0.732) and maximum value was achieved at lowest temperature of absorber. The exergy analysis shows that the destroyed exergy distribution in the components of the system depends powerfully on the temperatures of system. The increasing in the generator temperature of higher than 88°C increases the COP of the current system, and with a additional increase in the generator temperature, the COP value stays constant. The obtained results lead to the documentation of factors that may affect the exergy efficiency of the (H2O-LiBr) absorption system. It was found that the efficiency of the exergy of the system increased as a result of the increasing in the ambient temperature from (25°C to 45°C). The results show that the influence of system components condition on the total exergy loss is very significant.

Publisher

IOP Publishing

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3