Author:
Pilný Ondřej,Kalousek Lubor
Abstract
Abstract
Ventilated air cavities have been a mandatory part of thermally insulated pitched roofs in the Czech Republic. The purpose of these important elements is, among other things, primarily to prevent condensation of water vapor, which could otherwise endanger the roof structure and thus negatively affect the life of the entire composition. However, their thermal properties are often neglected and their overall design is overwhelmingly approached, due to the very difficult and complex calculation, as an empirical and normative matter without a higher link to the actual properties of the air cavity itself. It is therefore necessary that mentioned properties must be investigated more thoroughly, especially with increasing demands on thermal properties and increasingly extreme temperature fluctuations. This work describes a real full-scale experiment in which the properties of temperature and humidity of ventilated air cavities at the boundary with the external environment were measured. The composition of the experimental roof of the building was measured in all important layers, together with all the external and internal environmental conditions. The output is then a detailed course of behavior, which was analyzed and described.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Analysis of Construction Technology of Hospital Sloping Roof Engineering;Proceedings of the 2023 4th International Conference on Management Science and Engineering Management (ICMSEM 2023);2023-10-07
2. Ventilated Air Cavity – Annual Evaluation;Lecture Notes in Civil Engineering;2021-09-15