Author:
Prokeš J,Rozsypalová I,Girgle F,Daněk P,Štěpánek P
Abstract
Abstract
Fiber reinforced polymer (FRP) rebars have increasing popularity in the construction industry all around the world although steel rebars are widely used for reinforcing of the concrete so far. FRP bars, which have higher tensile strength compared to steel rebars with the same nominal diameter under normal conditions, are composed of resin matrix and fibers. In this paper, the load-bearing capacity of FRP reinforced concrete after elevated temperature exposition are present. The results are compared with concrete sample with steel reinforcement. Commercially produced glass FRP (GFRP) and carbon FRP (CFRP) rebars with sand coatings surface treatments were implemented in concrete beam and subjected to four-point bending load. The residual flexural strength of reinforced concrete after heating to 1000°C was obtained and evaluated and compared to results of non-heated elements. The results indicate that fire resistance of FRP reinforced beams can reach at least 60 minutes according the standard ČSN EN 13501-2.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献