Assessment of active filter on transformers connected three phase bridge converters

Author:

Kumar Ritesh,Ramya Laxmi D.,Shashi Kumar Reddy Ravula.,Thirupathi E.

Abstract

Abstract This paper starts with the benchmark analysis of shunt active power filter (SAPF) for adjustingeither compensations of harmonic current or compensating reactive power. Such equipment can capable of minimizing the content of harmonics present in the grid side generated by the non-linear loads. The proposed work represents the proficient responseof shunt active power filter for annihilates the contents of harmonics to keep the better quality of power supply.The implementation of SAPF on three-phase bridge (TPB) converters associated with cascaded single-stage transformers has been introduced.The transformers arrangements allow the compensator to utilize one dc-link unit that simplifies the management strategy and themode of operation. The system waveforms are provided by employing an appropriate pulse width modulation (PWM) technique having good co-relation with transformer turn ratio. System overview and easy maintenance create the projected SAPF has an efficient solution related with some standard previous configured model. The proposed model, PWM method and the control managements are given also as studies considering non-linear distortion and switching losses estimation. A MATLAB Simulink has been used to validate theImplementation of SAPF based on Cascaded Transformers Coupled with Three-Phase Bridge Converters.

Publisher

IOP Publishing

Subject

General Medicine

Reference15 articles.

1. Arrangement compensator dependent on fell transformers combined with three-stage connect converters;de Almeida,2015

2. Use of single-stage to three-stage converter engine drive systems with IGBT double module misfortunes decrease;Dias,2009

3. Versatile remuneration of responsive force with shunt dynamic force channels;Asiminoaei;IEEE transactions on industry applications,2008

4. A shunt dynamic channel dependent on voltage discovery for consonant end of an outspread force dissemination line;Akagi;IEEE transactions on industry applications,1999

5. Force quality improvement at medium-voltage networks utilizing hexagram dynamic force channel;Wen,2010

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Comparative evaluation of direct matrix converter using IGBT and power MOSFETs;AIP Conference Proceedings;2024

2. Switching on Device of a Two-Transformer Power Substation;2022 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM);2022-05-16