Abstract
Abstract
In this research article, the author has conducted the comparative thermal experimental analysis and investigation on Conventional still and Modified Evacuated Tubes solar still with different water volume of 30 and 50 Litre in Basin, in respect of Energy Balance Equation. The various variable elements have been taken into account and duly calculated for both the stills i.e. active still and passive still, based on thermal modelling. The variables calculated comprise inner glass surface temperature, distillate yield, basin water temperature etc. The entire study has been carried out at Akison’s Solar Equipments Pvt. Ltd., Shirwal, Maharashtra, India (latitude18.14° N: longitude 73.97° E), with adequate instrumental infrastructure setup appropriate for the purpose. The investigation concluded that there is substantial escalation of. 242% and 246% at 0.03 and 0.05m of water depth respectively in the yields obtained from Modified Evacuated Tubes solar still in comparison of Conventional still. It has been observed that theoretical outcomes from thermal modelling and the outcomes attained from experiments done for simple and modified stills are in respectable consensus.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献