A retrospective survey to establish institutional diagnostic reference levels for CT urography examinations based on clinical indications: preliminary results

Author:

Efthymiou Fotios O,Metaxas Vasileios I,Dimitroukas Christos P,Delis Harry B,Zikou Kiriaki D,Ntzanis Epameinondas S,Zampakis Petros E,Panayiotakis George SORCID,Kalogeropoulou Christina P

Abstract

Abstract Objective. To establish institutional diagnostic reference levels (IDRLs) based on clinical indications (CIs) for three- and four-phase computed tomography urography (CTU). Methods. Volumetric computed tomography dose index (CTDIvol), dose-length product (DLP), patients’ demographics, selected CIs like lithiasis, cancer, and other diseases, and protocols’ parameters were retrospectively recorded for 198 CTUs conducted on a Toshiba Aquilion Prime 80 scanner. Patients were categorised based on CIs and number of phases. These groups’ 75th percentiles of CTDIvol and DLP were proposed as IDRLs. The mean, median and IDRLs were compared with previously published values. Results. For the three-phase protocol, the CTDIvol (mGy) and DLP (mGy.cm) were 22.7/992 for the whole group, 23.4/992 for lithiasis, 22.8/1037 for cancer, and 21.2/981 for other diseases. The corresponding CTDIvol (mGy) and DLP (mGy.cm) values for the four-phase protocol were 28.6/1172, 30.6/1203, 27.3/1077, and 28.7/1252, respectively. A significant difference was found in CTDIvol and DLP between the two protocols, among the phases of three-phase (except cancer) and four-phase protocols (except DLP for other diseases), and in DLP between the second and third phases (except for cancer group). The results are comparable or lower than most studies published in the last decade. Conclusions. The CT technologist must be aware of the critical dose dependence on the scan length and the applied exposure parameters for each phase, according to the patient’s clinical background and the corresponding imaging anatomy, which must have been properly targeted by the competent radiologist. When clinically feasible, restricting the number of phases to three instead of four could remarkably reduce the patient’s radiation dose. CI-based IDRLs will serve as a baseline for comparison with CTU practice in other hospitals and could contribute to national DRL establishment. The awareness and knowledge of dose levels during CTU will prompt optimisation strategies in CT facilities.

Publisher

IOP Publishing

Subject

General Nursing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3