Can we improve electrocorticography using a circular grid array in brain tumor surgery?

Author:

Freund Brin EORCID,Sherman Wendy J,Sabsevitz David S,Middlebrooks Erik H,Feyissa Anteneh M,Garcia Diogo Moniz,Grewal Sanjeet S,Chaichana Kaisorn L,Quinones-Hinojosa Alfredo,Tatum William O

Abstract

Abstract Intraoperative electrocorticography (iECoG) is used as an adjunct to localize the epileptogenic zone during surgical resection of brain tumors in patients with focal epilepsies. It also enables monitoring of after-discharges and seizures with EEG during functional brain mapping with electrical stimulation. When seizures or after-discharges are present, they complicate accurate interpretation of the mapping strategy to outline the brain’s eloquent function and can affect the surgical procedure. Recurrent seizures during surgery requires urgent treatment and, when occurring during awake craniotomy, often leads to premature termination of brain mapping due to post-ictal confusion or sedation from acute rescue therapy. There are mixed results in studies on efficacy with iECoG in patients with epilepsy and brain tumors influencing survival and functional outcomes following surgery. Commercially available electrode arrays have inherent limitations. These could be improved with customization potentially leading to greater precision in safe and maximal resection of brain tumors. Few studies have assessed customized electrode grid designs as an alternative to commercially available products. Higher density electrode grids with intercontact distances less than 1 cm improve spatial delineation of electrophysiologic sources, including epileptiform activity, electrographic seizures, and afterdischarges on iECoG during functional brain mapping. In response to the shortcomings of current iECoG grid technologies, we designed and developed a novel higher-density hollow circular electrode grid array. The 360-degree iECoG monitoring capability allows continuous EEG recording during surgical intervention through the aperture with and without electrical stimulation mapping. Compared with linear strip electrodes that are commonly used for iECoG during surgery, the circular grid demonstrates significant benefits in brain tumor surgery. This includes quicker recovery of post-operative motor deficits (2.4 days versus 9 days, p = 0.05), more extensive tumor resection (92.0% versus 77.6%, p = 0.003), lesser reduction in Karnofsky Performance scale postoperatively (−2 versus −11.6, p = 0.007), and more sensitivity to recording afterdischarges. In this narrative review, we discuss the advantages and disadvantages of commercially available recording devices in the operating room and focus on the usefulness of the higher-density circular grid.

Publisher

IOP Publishing

Subject

General Nursing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3