Systematic end-to-end testing of multiple target treatments using the modular RUBY phantom

Author:

Brodbek LeonieORCID,Kretschmer Jana,Büsing Katrin,Looe Hui Khee,Poppe Björn,Poppinga DanielaORCID

Abstract

Abstract The RUBY head phantom in combination with the System QA insert MultiMet can be used for simultaneous point dose measurements at an isocentric and two off-axis positions. This study investigates the suitability of the system for systematic integral end-to-end testing of single-isocenter multiple target stereotactic treatments. Several volumetric modulated arc therapy plans were optimized on a planning CT of the phantom positioned in a stereotactic mask on the stereotactic treatment board. The plans were created for three artificial spherical target volumes centred around the measurement positions in the MultiMet insert. Target diameters between 5 and 40 mm were investigated. Coplanar and non-coplanar plans were optimized using the collapsed cone algorithm of the Oncentra Masterplan treatment planning system and recalculated with the Monte Carlo algorithm of the Monaco treatment planning system. Measurements were performed at an Elekta Synergy linear accelerator. The head phantom was positioned according to clinical workflow comprising immobilization and CBCT imaging. Simultaneous point dose measurements at all target positions were performed with three PinPoint 3D chambers (type 31022) as well as three microDiamond detectors (type 60019) and compared to the treatment planning system calculations. Furthermore, the angular dependence of the detector response was investigated to estimate the associated impact on the measured point dose values. Considering all investigated plans, PTV diameters and positions, the point doses calculated with the Monaco treatment planning system and the microDiamond measurements differed within 3.5%, whereas the PinPoint 3D showed differences of up to 6.9%. Point dose differences determined in comparison to the Oncentra Masterplan dose calculations were larger. The RUBY system was shown to be suitable for end-to-end testing of complex treatment scenarios such as single-isocenter multiple target plans.

Publisher

IOP Publishing

Subject

General Nursing

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3