Correction of Bowtie filter induced scatter signals based on air scan data and object scan data

Author:

Zhang GuoqingORCID,Wang Yang,Chen Wenhao,Li Taotao,Tian Yi

Abstract

Abstract In a cone beam CT system, a bowtie filter brings in additional scatter signals with respect to object induced scatter signals, which can degrade image quality and sometimes result in artifacts. This work aims to improve the image quality of CT scans by analyzing the contribution of bowtie filter induced scatter signals and removing them from projection data. Air calibration is a very useful preprocessing step to eliminate the response variations of detector pixels. Bowtie filter induced scattered x-ray signals of air scans are recorded in air calibration tables and therefore considered as a part of primary signals. However, scattered X-rays behave differently in scanned objects compared to primary x-rays. The difference should be corrected to eliminate the impact of bowtie filter induced scatter signals. A kernel based correction algorithm based on air scan data, named bowtie filter scatter correction algorithm, is applied to estimate and to eliminate the bowtie filter induced scatter signals in object scans. The scatter signals of air scans can be measured with air scans or retrieved from air calibration tables of a CT system, and can be used as input of the correction algorithm to estimate the change of scatter signals caused by the scanned objects in the scan field. Based on the assumption that the scatter signals in the projection data scanned with narrow collimation can be neglected, the difference signals between narrow and broad collimations can be used to estimate bowtie filter induced scatter signals for air scans with the correction of extra-focal radiations (EFRs). The calculated bowtie filter induced scatter signals have been compared with the results of Monte Carlo simulations, and the parameters of correction algorithm have been determined by fitting the measured scatter signal curves of phantom scans with calculated curves. Projection data have been reconstructed using Filtered BackProjection (FBP) method with and without bowtie filter correction to check whether the image quality is improved. Scatter signals can be well approximated with the bowtie filter scatter correction algorithm together with an existing object scatter correction algorithm. After removing the bowtie filter induced scatter signals, the dark bands in reconstructed images in the regions near the edges of scanned objects can be mostly eliminated. The difference signals of air scan data between narrow and broad collimations can be used to estimate the bowtie filter induced scatter for air scans. The proposed bowtie filter scatter correction algorithm using air scan data can be applied to estimate and to remove most of the bowtie filter induced scatter signals in object scans.

Publisher

IOP Publishing

Subject

General Nursing

Reference31 articles.

1. Scatter correction methods in dimensional ct;Bär;iCT,2012

2. Hybrid scatter correction for ct imaging;Bär;Phys. Med. Biol.,2012

3. Convolution-based scatter correction using kernels combining measurements and monte carlo simulations;Bhatia;J. X-Ray Sci. Technol.,2017

4. Ct artifacts: causes and reduction techniques;Boas;Imaging in Medicine,2012

5. Effect of scattered radiation on image noise in cone beam ct;Endo;Med. Phys.,2001

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3