Carbon-11 and Carbon-12 beam range verifications through prompt gamma and annihilation gamma measurements: Monte Carlo simulations

Author:

Chalise Ananta RajORCID,Chi Yujie,Lai Youfang,Shao Yiping,Jin MingwuORCID

Abstract

Abstract Range uncertainty remains a big concern in particle therapy, as it may cause target dose degradation and normal tissue overdosing. Positron emission tomography (PET) and prompt gamma imaging (PGI) are two promising modalities for range verification. However, the relatively long acquisition time of PET and the relatively low yield of PGI pose challenges for real-time range verification. In this paper, we explore using the primary Carbon-11 (C-11) ion beams to enhance the gamma yield compared to the primary C-12 ion beams to improve PET and PGI by using Monte Carlo simulations of water and PMMA phantoms at four incident energies (95, 200, 300, and 430 MeV u−1). Prompt gammas (PGs) and annihilation gammas (AGs) were recorded for post-processing to mimic PGI and PET imaging, respectively. We used both time-of-flight (TOF) and energy selections for PGI, which boosted the ratio of PGs to background neutrons to 2.44, up from 0.87 without the selections. At the lowest incident energy (100 MeVu-1), PG yield from C-11 was 0.82 times of that from C-12, while AG yield from C-11 was 6 ∼ 11 folds higher than from C-12 in PMMA. At higher energies, PG differences between C-11 and C-12 were much smaller, while AG yield from C-11 was 30%∼90% higher than from C-12 using minute-acquisition. With minute-acquisition, the AG depth distribution of C-11 showed a sharp peak coincident with the Bragg peak due to the decay of the primary C-11 ions, but that of C-12 had no such one. The high AG yield and distinct peaks could lead to more precise range verification of C-11 than C-12. These results demonstrate that using C-11 ion beams for potentially combined PGI and PET has great potential to improve online single-spot range verification accuracy and precision.

Funder

National Cancer Institute

National Institute of Biomedical Imaging and Bioengineering

Publisher

IOP Publishing

Subject

General Nursing

Reference42 articles.

1. Recent developments in GEANT4;Allison;Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip.,2016

2. New developments of 11C post-accelerated beams for hadron therapy and imaging;Augusto;Nucl. Instruments Methods Phys. Res. B,2016

3. Implementation and initial clinical experience of offline PET/CT-based verification of scanned carbon ion treatment;Bauer;Radiother. Oncol.,2013

4. High energy beams of radioactive nuclei and their biomedical applications;Chatterjee;Int. J. Radiat. Oncol. Biol. Phys.,1981

5. Modeling parameterized geometry in GPU-based Monte Carlo particle transport simulation for radiotherapy;Chi;Phys. Med. Biol.,2016

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3