3D printed heterogeneous paediatric head and adult thorax phantoms for linear accelerator radiotherapy quality assurance: from fabrication to treatment delivery

Author:

Bustillo John Paul OORCID,Posadas Julia Rebecca D,Mata Jacob L,Inocencio Elrick T,Rosenfeld Anatoly BORCID,Lerch Michael L FORCID

Abstract

Abstract Objective. This study aims to design and fabricate a 3D printed heterogeneous paediatric head phantom and to customize a thorax phantom for radiotherapy dosimetry. Approach. This study designed, fabricated, and tested 3D printed radiotherapy phantoms that can simulate soft tissue, lung, brain, and bone. Various polymers were considered in designing the phantoms. Polylactic acid+, nylon, and plaster were used in simulating different tissue equivalence. Dimensional accuracy, and CT number were investigated. The phantoms were subjected to a complete radiotherapy clinical workflow. Several treatment plans were delivered in both the head and the thorax phantom from a simple single 6 MV beam, parallel opposed beams, and five-field intensity modulated radiotherapy (IMRT) beams. Dose measurements using an ionization chamber and radiochromic films were compared with the calculated doses of the Varian Eclipse treatment planning system (TPS). Main results. The fabricated heterogeneous phantoms represent paediatric human head and adult thorax based on its radiation attenuation and anatomy. The measured CT number ranges are within −786.23 ± 10.55, 0.98 ± 3.86, 129.51 ± 12.83, and 651.14 ± 47.76 HU for lung, water/brain, soft tissue, and bone, respectively. It has a good radiological imaging visual similarity relative to a real human head and thorax depicting soft tissue, lung, bone, and brain. The accumulated dose readings for both conformal radiotherapy and IMRT match with the TPS calculated dose within ±2% and ±4% for head and thorax phantom, respectively. The mean pass rate for all the plans delivered are above 90% for gamma analysis criterion of 3%/3 mm. Significance and conclusion. The fabricated heterogeneous paediatric head and thorax phantoms are useful in Linac end-to-end radiotherapy quality assurance based on its CT image and measured radiation dose. The manufacturing and dosimetry workflow of this study can be utilized by other institutions for dosimetry and trainings.

Funder

Department of Science and Technology Philippines

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3