Comparative evaluation of image quality between virtual grid and grid portable radiographic systems

Author:

Siddique Azmul HORCID,Ge Gary,Zhang Jie

Abstract

Abstract Purpose. Virtual Grid (VG) is an image processing technique designed to address scattered radiation from radiographic systems without a physical grid. It aims to eliminate artifacts caused by grid misalignment and enhance radiographic workflow efficiency. We intend to evaluate image quality between Virtual Grid and grid-based radiographic systems across various patient thicknesses. Methods. A Fujifilm Virtual Grid and GE AMX-4 portable radiographic system was used. Image quality was assessed using MTF, NPS, LCR, and CNR. MTF calculations employed an edge-device method with a 0.1 mmCu sheet. For NPS evaluation, uniform images were acquired with multiple 30 × 30 cm solid water blocks (2 cm thick), overlaid in 2 cm increments to simulate patient sizes from 2cm to 40 cm. LCR and CNR were evaluated using a CIRS test plate with 9-hole depths for a hole diameter of 0.375’. The test object was placed on top of the detector then water blocks, while maintaining the same SID, beam quality, and exposure between the units. Visual assessments were conducted by four readers, quantifying perceived hole numbers. The weighted Cohen’s Kappa and Welch’s T-test were utilized for statistical analysis. Results. At 80% MTF, VG exhibited high contrast resolution of 1.1 l p/mm compared to 1.2 l p/mm for the grid system. VG demonstrated lower noise levels across all frequencies for equivalent patient thicknesses. Welch’s T-test indicated no significant differences in LCR (P = 0.31) and CNR (P = 0.34) between the systems. However, qualitative observation demonstrated VG’s better low contrast response for patient sizes ≥10 cm. The average weighted Cohen’s Kappa value was 0.78. Conclusion. This work indicates the Virtual Grid technology can effectively mitigate scattered radiation to improve granularity and low-contrast resolution in an image compared to a grid system. Furthermore, it can potentially reduce patient dose.

Publisher

IOP Publishing

Reference11 articles.

1. Improvement in image quality and workflow of x-ray examinations using a new image processing method, Virtual Grid™ Technology [White paper];Imaging Technology Center, Fujifilm Corporation;Fujifilm,2014

2. Evaluation of virtual grid processed clinical chest radiographs;Gossye;Invest Radiol,2022

3. Evaluation of virtual grid processed clinical pelvic radiographs;Gossye;J. Appl. Clin. Med. Phys.,2024

4. A method for measuring the presampled MTF of digital radiographic systems using an edge test device;Samei;Med. Phys.,1998

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3