Theoretical and experimental evaluation of the distance dependence of fiber-based fluorescence and reflection measurements for laser lithotripsy

Author:

Lange BirgitORCID,Ozimek Tomasz,Wießmeyer Judith Riccarda,Kramer Mario W,Merseburger Axel S,Brinkmann Ralf

Abstract

Abstract Objectives. In laser lithotripsy, a green aiming beam overlying the infrared (IR) treatment radiation gives rise to reflection and fluorescence signals that can be measured via the treatment fiber. While stone autofluorescence is used for target detection, the condition of the fiber can be assessed based on its Fresnel reflection. For good applicability, fluorescence detection of stones should work even when the stone and fiber are not in direct contact. Fiber breakage detection, on the other hand, can be falsified if surfaces located in front of the fiber reflect light from the aiming laser back into it. For both applications, therefore, a fundamental investigation of the dependence of the signal amplitude on the distance between fiber and surface is important. Methods. Calculations of the signal drop of fluorescence or diffuse and specular reflection with increasing fiber distance were performed using ray tracing based on a simple geometric model for different fiber core diameters. Reflection signals from a mirror, diffuse reflector, human calculi, and porcine renal tissue placed in water were measured at varying distances (0–5 mm). For human calculi, fluorescence signals were recorded simultaneously. Results. The calculations showed a linear signal decrease down to ∼60% of the maximum signal (fiber in contact). The distance z at which the signal drops to for example 50% depends linearly on the diameter of the fiber core. For fibers used in lithotripsy and positioned in water, z 50% ranges from 0.55 mm (200 μm core diameter) to 2.73 mm, (1 mm core diameter). The calculations were in good agreement with the experimental results. Conclusions. The autofluorescence signals of stones can be measured in non-contact mode. Evaluating the Fresnel signal of the end face of the fiber to detect breakage is possible unless the fiber is situated less than some millimeters to reflecting surfaces.

Publisher

IOP Publishing

Subject

General Nursing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3