A convolution-superposition fluence model for the Siemens HD120 multi leaf collimator with application to a 3D VMAT dose engine

Author:

Steciw StephenORCID

Abstract

Abstract Purpose. To construct a fast-calculating fluence modelfor the Siemens HD120 multi leaf collimator (MLC) using convolution-superposition techniques, and to develop a 3D VMAT dose engine using this fluence model.  This work offers analternative to time-consuming open-source Monte Carlo simulations for thosedeveloping in-house dose-calculating software for research or clinical needs.Methods. EPID-acquired images of sweeping-window and sweeping-checker field profiles were used to commission transmission, 2 Dinterleaf leakage, and tongue-and-groove maps specific to the HD120 MLC.  These maps, along with a 2D head-scattermodel were incorporated into a convolution-superposition algorithm to provide a fluence model for the HD120 MLC. This fluence model was used to develop a 3D VMAT dose engine, where 3D pre-computed 6MV dose kernels (EGSnrc) and a 3D fluence curvature-correction map were incorporatedto calculate 3D VMAT doses in a 22 cm diameter cylindrical phantom. Four VMAT patient plans witha large range of PTV sizes (36 cc to 604 cc) were chosen to test the fluence model and dose engine. Results. Excellent agreement was observed between the simulated commissioning fields and measured EPID-responses. 2D 2%/2 mm gamma analysis yielded a 98.9% pass rate for 1 cm, 2 cm, and 4 cm sweeping-window fields. 2D 2%/2mm gamma analysis for outer/inner MLC leaves yielded 89.1%/77.0% and 95.2%/91.1% pass rates from 1 cm and 2 cm sweeping-checker fields. Mean 3%/3 mm gamma analysis showed excellent agreement between our dose engine and Eclipse (Acuros) regardless of PTV size: 98.7% pass rate, with 95.1% pass rate in the high-dose volume.  Fluence calculation times were13.6 seconds per dynamic MLC field and 1.4 minutes/arc for 3D VMAT dose on a standard PC. Conclusions. A fast-calculating convolution-superposition fluence model has been commissioned for the Siemens HD120 MLC and incorporatedinto a 3D VMAT dose engine.  This work can be used to facilitate the development of fast in-house dose-calculating software.

Publisher

IOP Publishing

Subject

General Nursing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3