Mean Arc Distance (MAD): a quantity to compare trajectory 4π sampling in single target cranial stereotactic radiotherapy

Author:

MacDonald R LeeORCID,Lincoln John,Church Cody,Thomas Christopher,Syme AlasdairORCID

Abstract

Abstract Purpose. C-arm linac-based radiotherapy has seen a recent interest in 4π methods of delivery using simultaneous rotations of couch and gantry to reduce doses to organs-at-risk (OARs) and increase dose compactness. While many methods use heuristics to generate trajectories that avoid OARs, combined with arbitrary trajectory restrictions to prevent oversampling, a quantity has not yet been developed to succinctly compare sampling of the 4π space for candidate trajectories as a surrogate for dosimetric compactness. Methods. Evenly spaced sampling points were distributed across a 4π sphere centred on isocentre. A metric, mean arc distance (MAD), was defined that quantifies the average arc distance between all sampling points and their nearest field in a radiotherapy trajectory. The relationship between isodose volume and MAD was examined in 2,047 plans: 900 unique trajectories of fixed port DCA plans, 900 unique trajectories of contiguous field DCA plans, 192 VMAT plans (eight volumes in four locations, each with six trajectories) in matRad with 5 VMAT plans repeated for validation in a clinical planning system, and 10 clinical VMAT cases replanned with five trajectories in a clinical treatment planning system. Results. All isodose volumes greater than 10% of the prescription dose decreased with decreasing MAD in all comparisons. In the range of 10% to 100% of the prescription dose, the rate of isodose volume decrease was exponential as a function of MAD in all comparisons. Reduction of absolute isodose volume is seen with increased 4π sampling, with larger target volumes exhibiting larger absolute reductions. Very low isodoses (0% to 10% of prescription) increased with decreasing MAD. Conclusions. MAD is a 4π sampling quantity useful in quantifying the decrease of isodose volume, relevant for sparing normal tissues. By quantifying this feature, candidate dynamic trajectories can be efficiently compared for 4π sampling. This quantity is explored here for single target cranial radiotherapy but may have applications to other radiotherapy treatment sites.

Publisher

IOP Publishing

Subject

General Nursing

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3