Spatial accuracy of the stereotactic Leksell® Vantage™ head frame in comparison with the standard stereotactic Leksell® G Frame for Gamma-Knife

Author:

Vincent MarionORCID,Michel-Amadry Géraldine,Nigoul Jean-Marc,Beltaïfa YassineORCID,Régis Jean

Abstract

Abstract Purpose. Since January 2021, the Leksell® Vantage head frame (V-frame) is used for Gamma Knife® treatments in addition to the historical Leksell® G-Frame known as the reference. The aim of this study was to compare the spatial accuracy of treatments with these two frames. Methods. Firstly, the constancy of the geometric accuracy of the system according to the Elekta quality assurance process was carried out during sixteen months with V and G–frames’ adaptors. Then, End-to-end test was carried out with both V and G-frame using an anthropomorphic phantom and Gafchromic® films. The overall precision of the radiation center was calculated as the displacement vector for a 4 mm collimator shot. Additionally, the Cone Beam Computed Tomography (CBCT) positioning system was used to assess the precision of the Leksell coordinates system defined by V-frames on 64 patients in comparison to G-frames for 46 patients. To ensure that patient’s head movement was not possible during treatment with the V-frame, the High Definition Motion Management (HDMM) system was used and a final CBCT was performed at the end of the irradiation. Results. The QA constructor’s tests done with the G-frame and V-frame adaptor gave similar results over sixteen months. End-to-end tests demonstrated that the mean positioning accuracy was 0.54 mm (SD of 0.14 mm) and 0.70 mm (SD of 0.14 mm) with V-frame and G-frame respectively. The displacement vector given by CBCT ranged from 0.02 to 1.05 mm with a mean value of 0.38 mm (SD of 0.18 mm) for the 64 V-framed patients and from 0 to 0.92 mm with a mean value of 0.31 mm (SD of 0.18 mm) for the 46 G-framed patients. The mean translation movement between the beginning and the end of the 64 treatments with V-frame was 0.08 mm (SD of 0.04 mm, maximum value of 0.19 mm). Conclusion. We estimated that V-frames are as precise as G-frames with a targeting accuracy of less than 1 mm.

Publisher

IOP Publishing

Subject

General Nursing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3