Abstract
Abstract
Background: Multi-slice, multiple breath-hold ECG-gated 2D cine MRI is a standard technique for evaluating heart function and restricted to one or two images per breath-hold. Therefore, the standard cine MRI requires long scan time and can result in slice-misalignments because of various breath-hold locations in the multiple acquisitions. Methods: This work proposes the sc-GROG based k-t ESPIRiT with Total Variation (TV) constraint (sc-GROG k-t ESPIRiT) to reconstruct unaliased cardiac real-time cine MR images from highly accelerated whole heart multi-slice, single breath-hold, real-time 2D cine radial data acquired using the balanced steady-state free precession (trueFISP) sequence in 8 patients. The proposed method quality is assessed via Artifact Power (AP), Root-Mean Square Error (RMSE), Structure Similarity Index (SSIM), Peak Signal-to-Noise Ratio (PSNR), blood-pool to myocardial Contrast-to-Noise-Ratio (CNR), Signal-to-Noise-Ratio (SNR) and spatial-temporal intensity plots through the blood-myocardium boundary. The proposed method quantitative results are compared with the NUFFT based k-t ESPIRiT with Total Variation (TV) constraint (NUFFT k-t ESPIRiT) approach. Furthermore, clinical analysis and function quantification are assessed by Bland–Altman (BA) analyses. Results: As supported by the visual assessment and evaluation parameters, the reconstruction results of the sc-GROG k-t ESPIRiT approach provide an average 21%, 12%, 1% and 47% improvement in AP, RMSE, SSIM and PSNR, respectively in comparison to the NUFFT k-t ESPIRiT approach. Furthermore, the proposed method gives on average 45% and 58% improved blood-pool to myocardial CNR and SNR than the NUFFT k-t ESPIRiT approach. Also, from the BA plot, the proposed method gives better left ventricular and right ventricular function measurements as compared to the NUFFT k-t ESPIRiT scheme. Conclusions: The sc-GROG k-t ESPIRiT (Proposed Method) improves the spatio-temporal quality of the whole heart multi-slice, single breath-hold, real-time 2D cine radial MR and semi-automated analysis using standard clinical software, as compared to the NUFFT k-t ESPIRiT approach.
Funder
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung