Comparison of single catheter versus dual catheter-based EBT3 film calibration for the Ir-192 beam energy

Author:

Trivedi GauravORCID,Singh Pushpendra PORCID,Oinam Arun S

Abstract

Abstract Purpose. Films and TLDs have been the common choices for passive in-vivo dose measurement in radiotherapy. In the brachytherapy applications, it is very difficult to report and verify the dose at multiple localized high dose gradient regions and also the dose to organ at risk. This study was carried out to introduce a new and accurate calibration method for GafChromic EBT3 films irradiated using Ir-192 photon energy from miniature High Dose Rate (HDR) Brachytherapy source. Materials and methods. Film holder made of Styrofoam was used to hold the EBT3 film at its center. It was placed inside the mini water phantom and the films were irradiated by Ir-192 source of microSelectron HDR afterloading brachytherapy system. Two different setups: Single catheter-based film exposure and dual catheter-based film exposure were compared. The films scanned on a flatbed scanner were analysed in three different color channels: red, green, and blue using Image J software. The dose calibration graphs were generated using the third-order polynomial equations fitted on the data points from two different methods of calibration procedure. Maximum and mean dose difference between TPS calculated and measured was analyzed. Results. The measured dose difference from the TPS calculated doses were evaluated for the three groups of dose ranges (low, medium and high). In the high dose range, standard uncertainty of dose difference are ±2.3%, ±2.9%, and ±2.4% respectively for the red, green, and blue color channel when the TPS calculated dose was compared with single catheter based film calibration equation. Whereas it is observed as 1.3%, 1.4% and 3.1% for the red, green, and blue color channels respectively when compared with the dual catheter based film calibration equation. A test film was exposed to a TPS calculated dose of 666 cGy to validate the calibration equations, single catheter based film calibration equation estimated the dose difference as −9.2%, −7.8% and −3.6% respectively in the red, green, and blue color channels whereas the same were observed as 0.1%, 0.2% and 6.1% respectively when dual catheter based film calibration equation was applied. Conclusion. Source miniature size, reproducible positioning of the film and catheter system inside water medium are the major challenges in the film calibration with Ir-192 beam. To overcome these situations dual catheter-based film calibration was found more accurate and reproducible as compare to the single catheter based film calibration.

Publisher

IOP Publishing

Subject

General Nursing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3