Does the Inion OTPSTM absorbable plating system induce higher foreign-body reaction than titanium implants? An experimental randomized comparative study in rabbits

Author:

Chalidis ByronORCID,Kitridis Dimitrios,Savvidis Panagiotis,Papalois Apostolos,Givissis Panagiotis

Abstract

Abstract Hardware removal after complete fracture healing is a laborious and traumatic procedure that bears the risks of refracture, infection, and soft tissue damage. Absorbable materials for fracture fixation have the advantage of eliminating the need for removal; however, they may stimulate a considerable inflammatory response. For that reason, we compared in a prospective randomized experimental animal model study the incidence of foreign-body reactions between Inion OTPSTM absorbable plate implants, consisting of carbon trimethylene, L-polylactic acid, and D, L-polylactic acid, and conventional titanium plates. Seventy rabbits were equally divided into two groups. Titanium (Group A) or absorbable (Group B) plates and screws were implanted in the femoral shaft of the rabbits. Wound reaction and laboratory tests including white blood cell count (WBC), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) values were measured and compared at different time points. Radiographs and histological analysis of tissue samples from all animals were also used to identify potential foreign-body reactions. WBC showed normal values in both groups. In Group A, ESR levels were higher at all time points but CRP values were normalized at 3 weeks postoperatively. In Group B, ESR and CRP levels reached a peak at 3 weeks and were above normal values throughout the whole experiment (p < 0.001). Radiologic examination revealed periosteal thickening and surrounding sclerosis in 23 out of 35 animals of Group B (66%). All Group A animals had normal radiographic findings. Histopathology showed a typical non-specific foreign-body reaction in all animals in Group B (100%) but none in Group A. However, only four of them (11.8%) developed non-infected wound complications and showed significantly elevated CRP and ESR values (p = 0.054). Although Inion OTPSTM Biodegradable Plating System stimulates a foreign-body reaction, only a small but not negligible percentage of almost 12% may lead to wound problems. However, this difference compared to titanium plates was of borderline not statistically significant. Future studies should focus on the development of absorbable implants with improved biocompatibility aiming to further decrease the potential of foreign-body reaction and eliminate the need for additional reoperative procedures.

Funder

The research was funded by and performed in the facilities of the Experimental – Research Centre ELPEN, Athens, Greece

Publisher

IOP Publishing

Subject

Biomedical Engineering,Biomaterials,Bioengineering

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3