Author:
Wu Huikai,Zhou Yijun,Luo Chen,Si Buchao
Abstract
Abstract
The wafer pre-alignment device is a crucial component of the equipment front-end modules (EFEM) in the integrated circuit (IC) manufacturing industry. It corrects the wafer position and orientation errors before the wafer is transferred to the subsequent fine alignment wafer stage. To solve the calibration problem of a q-X-Z type wafer pre-alignment device, the study establishes its kinematic model and constructs the relationship between each axis and a laser sensor. Compared to the conventional method of directly selecting 4 points’ wafer edge data to achieve calibration, this paper proposes a method that makes full use of the edge data of a square calibration board. This method solves the device parameters through iteration based on coarse to fine thoughts and obtains a calibration accuracy within 10 microns. The statistical accuracy and operational repeatability of the proposed method are verified through a series of calibration experiments of the wafer pre-alignment device.
Reference8 articles.
1. A Dual Vacuum Wafer Prealigner and a Multiple Level Structure;Kim;Transactions of The Korea Fluid Power Systems Society,2011
2. A wafer pre-alignment system using one image of a whole wafer;Koo;Journal of the semiconductor & display technology,2010
3. A wafer prealignment algorithm based on Fourier transform and least square regression;Xu;IEEE Transactions on Automation Science and Engineering,2017
4. A Wafer Pre-Alignment Algorithm Based on Weighted Fourier Series Fitting of Circles and Least Squares Fitting of Circles;Chen;Micromachines,2023