Abstract
Abstract
In order to reduce the moisture content of flue gas in coal-fired power plants, this paper puts forward a novel spraying system with upward spraying and downward gas flow (ST-UD). And the heat and mass transfer models of ST-UD in fluent were validated against experiment data. Then orthogonal simulation experiment was carried out to get the relationship between the four influence factors and the two evaluation indices. Through the range analysis and trend analysis, it can be found that the influence degree and the influence trend of factors on evaluation indices. The conclusion of this paper provides a reference for the heat-transfer performance optimization of other spray towers.