Fouling effect in a shell-and-tube heat exchanger with twisted tape inserts applied to a small-scale biomass gasification power plant

Author:

Allesina Giulio,Pedrazzi Simone,Ottani Filippo,Tartarini Paolo

Abstract

Abstract In this work the over-time behaviour of a shell-and-tube type heat exchanger applied to a commercial and small-scale wood biomass gasification system was investigated. The heat exchanger, equipped with twisted tape turbulators, was used to cool down the syngas produced by the power plant. An experimental campaign was conducted to evaluate the performance trend in the first 15 hours of operation. The results showed an increase in heat transfer which led to a progressive reduction of the gas outlet temperature from 105.4 °C to 90.0 °C. The data collected confirm the literature studies on the positive effect that the deposits of particulate matter and tars have in reducing the clearance between the heat exchanger pipes and the turbulators, providing information for the temporal optimization of the cleaning strategy of the heat exchanger itself.

Publisher

IOP Publishing

Subject

Computer Science Applications,History,Education