Author:
Zhao Jinghe,Tan Qingchang,Jiang Bo,Hu Jing,Liu Siyuan
Abstract
Abstract
The line structured light vision has better robustness and higher measurement accuracy as an active vision measurement method, which is widely used in the measurement of component size and shape tolerance. The calibration is a key technology of vision measurement. The calibration accuracy is not only affected by the calibration algorithm, but the parameters of the hardware equipment also have an important impact on the final calibration accuracy. Based on the analysis of the calibration algorithm, this paper conducts a theoretical analysis on the selection of the main hardware parameters, and uses the orthogonal experiment method to determine the relationship between the equipment parameters and the calibration accuracy. In the experiments, the aperture has the greatest impact on the calibration accuracy among the main equipment parameters, and the calibration accuracy is the highest when the camera aperture is between F4-F8.
Subject
General Physics and Astronomy
Reference13 articles.
1. Measurement of shaft diameters by machine vision;Guang;Appl. Opt.,2010
2. A Planar-Dimensions Machine Vision Measurement Method Based on Lens Distortion Correction;Qiucheng;Sci. World J. Opt.,2013
3. Shaft diameter measurement using a digital image;Qiucheng;Opt. Lasers Eng.,2014
4. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses [J];Tsai;IEEE Journal of Robotics and Automation,1987
5. Geometric camera calibration using circular control points [C];Heikkila,2000
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献