Effect of Computed Tomography Slice Thickness on Calculated Coronary Artery Calcium Score in the Assessment of Possible Radiation Induced Cardiac Toxicity

Author:

Alexander C.,Rajapakshe R.

Abstract

Abstract Studies have suggested that the occurrence of radiation induced cardiac toxicity in breast cancer patients is significantly higher in women with pre-existing cardiac risk factors. Therefore, it is important to quantify the relationship between radiation induced cardiac toxicity and a measurable level of pre-existing cardiac risk such as the patient’s coronary artery calcium Agatston score. To assess the extent of coronary artery calcium present in the walls of patients’ coronary arteries before they received treatment, Agatston scores may be calculated using thoracic CT scans acquired for external beam radiotherapy planning. However, these planning CT scans can vary in slice thickness and resolution, thus complicating the calculation of calcium scores using scans with slice thicknesses other than the 3mm routinely employed for traditional Agatston scoring. The objective of this project is to quantify the effect of varying CT scan slice thickness in the calculation of coronary artery calcium scores so that a method of standardization might be developed. This is accomplished through the design, fabrication, and scanning of an anthropomorphic phantom featuring calcium inserts of varying sizes. Analysis of how the scores change with increasing slice thickness is used to construct a simple linear scaling method of standardization which corrects for varying slice thickness and the resulting partial volume distortions. A linear scaling method was successfully validated for the calculation of coronary artery calcium Agatston scores across a range of slice thicknesses increasing from 0.625 mm to 5 mm. Scaling is applied by multiplying the score by the slice thickness and dividing by 3 mm. This method is potentially applicable in any clinical or research endeavour which calls for retroactive cardiac calcium quantification. With a simple linear scaling method, external beam radiation therapy planning CT scans with slice thicknesses ranging from 0.625 mm to 5 mm can be used to calculate coronary artery calcium Agatston scores and thereby measure a patient’s level of cardiac risk before treatment.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3