Author:
Deng Cong,Zhao Zhongxun,Hu Huasheng,Li Xufeng,Luo Weijian
Abstract
The corrosion problems of TA4 titanium alloy trays were urgent to be solved in the safe and steady production process of the acetic acid distillation column. According to the real corrosion environment of the distillation column, the corrosion behavior of TA4 titanium alloy in simulated azeotropic acetic acid solutions with a series of I- and Cl- concentrations was investigated by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization measurements. The experimental results showed that the TA4 titanium alloy was much easier to be corrosive with I- and Cl- in the test solution, the passive film resistance R
f, the charge transfer resistance R
ct, and Warburg impedance W decreased obviously with the increasing concentration of I- and Cl-. The corrosion rate of Cl- was 1.79 times higher than I- on average when the I- and Cl- concentration increased from 0.1 wt.% to 5 wt.%. The inhibition of passive film formation on the surface of TA4 titanium alloy by Cl- is stronger than that of I-.
Subject
General Physics and Astronomy
Reference25 articles.
1. Corrosion behaviour of titanium in non-aqueous solvents;Trasatti;Mater. Chem. Phys,2005
2. Titanium and its alloys as key materials for corrosion protection engineering;Mitsuo;Nippon Steel Technical Report,2003
3. Improvement of corrosion resistance of NiTi sputtered thin films by anodization;Bayat;Appl. Surf. Sci,2011