Abstract
Medical diagnostic information has been a change in clinical medicine development, including medical image and computer technology. The paper aims to determine the threshold for the 3D-IRP with a multislice Computerized Tomography Scan (CT-Scan). The 3D-IRP method is the IMCA technique. Skull and Sternum are the focus of the 3D medical image. It is in the multislice CT-Scan format of Digital Imaging and Communications in Medicine (DICOM). Surface volume and area, and visual shape are performance criteria of the 3D-IRP are matching with a software package (InVesalius ver. 3.1). The optimum threshold for the 3D bone representation of objects is 210. The difference in 3D image surface area and volume between the prototype's performance and the software package is smaller than 0.50%. Based on the three radiologists, the Skull and Sternum's visual shape is roughly 100% balanced.
Subject
General Physics and Astronomy
Reference18 articles.
1. Medical Image Reconstruction Based on ITK and VTK;Hui,2013
2. 3D Reconstruction of Face from 2D CT Scan Images;Senthil;Procedia Engineering,2012
3. Development of Medical Props Production Towards Industry 4.0;Ignatius,2018
4. Quantitative Comparison of Freeware Software for Bone Mesh from DICOM Files;Katsiaryna;Journal of Biomechchanics