Loshkarev I Yu,Sterhov A I,Petrov K A
Abstract
Abstract
In this article, we simulated the parametrs of an acrylic and specular light pipe to transmit radiation from the LED matrix. The results of the experiment can be estimated using the dependence of the light flux on the number of reflections in the specular light pipe. Evaluation was conducted in the software package “Mathcad”. The possibility of providing illumination from 6 to 30 lx using the system of transportation of artificial light of roads \ streets \ squares depends on the class of the object. The study of the transmission of light through a specular and acrylic light pipe has shown that under equal conditions of light transport (the same power, the same aperture, the equal length of the light pipe, the same diameter of the light pipe), the acrylic fiber has the advantage. Losses using acrylic light pipe of 2000 mm are 24% whereas using specular light pipe they are 45%. However, if there is no limitation in the diameter of the light pipe, then it is preferable to use a specular one. For example, at 150 mm the losses are no more than 13%, which is not achieved with an acrylic light pipe even with a diameter of 10 mm, since when the radiation aperture is kept, a reduction in diameter leads to an increase of the interaction of the radiation with the walls of the acrylic rod and increase of the optical path.
Subject
General Physics and Astronomy
Reference10 articles.
1. The effectiveness of the implementation of light guides for lighting in livestock buildings;Loshkarev;News of the International Academy of Agrarian Education,2018