Author:
Bogdanov A A,Eremin I V,Chichagov Yu V,Eremin V K,Tuboltsev Yu V,Verbitskaya E M,Bezbah A A,Fomichev A S,Kiselev O A,Kostyleva D A
Abstract
Abstract
A new two-coordinate position-sensitive spectrometer for the measurements of spatial and energy distribution of ionizing particles was developed. The sensitive elements of the device are two orthogonal 64 strip semiconductor detectors whose signals are read out by two Application-Specific Integrated Circuits (ASIC) IDE1140 comprising 64 spectrometric channels each. Control, pre-processing data acquisition and transfer to a computer are carried out using FPGA circuit EP3C16Q240. The main spectrometer characteristics obtained in the measurements are: equivalent noise charge of 0.7 fC and integral nonlinearity is below 1% in the range from 5 to 160 fC.
Subject
General Physics and Astronomy
Reference5 articles.
1. A prototype silicon detector system for space cosmic-ray charge measurement;Fei;Chinese Phys. C,2014
2. Strip detector for the ATLAS detector upgrade for the high-luminosity LHC;Madaffari,2017
3. The ACCULINNA-2 project: The physics case and technical challenges;Fomichev;Eur. Phys. J. A,2018
4. First EXL experiment with stored radioactive beam: Proton scattering on 56Ni;von Schmid;EPJ Web of Conferences,2014
5. Position-Sensitive Spectrometric Module for Detecting Ionizing Radiation by Semiconductor Strip Detectors;Tubol’tsev;Tech. Phys. Lett.,2018