Evaluation of Typical Dose Rate Values, Maximum Dose Rate in Air and Dose Rate in Surface Image Intensifier (Ii) in Dual Function Fluoroscopy (Fl)

Author:

Bariah K,Dewang S,Suryani S

Abstract

Abstract This study aims to determine the value of the typical dose rate, the maximum dose rate in the air and the dose rate on the surface of Image Intensifier (II) in 3 types of dual function Fluoroscopy (FL). This study used a dual function Fluoroscopy, X-Ray safe multimeter, Pb plate, Cu plate, and phantom perspek. Typical dose rate measurement were carried out by placing a multimeter X-Ray of phanrom perspek of a thickness of 18 cm, so that the examination table distance from the detector was 18 cm and source distance from image of 96 cm according to normal patient position. Measuring the maximum dose rate in teh air is done by placing the detector at distance of 300 mm above the examination table, placing the Pb 2 mm below the collimator, the exposure is carried out at the maximum automatic kVp. Measuring the dose rate of the surface Image Intensifier (II) is done by placing the detector above II, the Cu plate with a thickness of 2 mmCu is affixed to the surface of the collimator and the exposure is carried out on the automatic kVp. Typical dose rated to test results from FL (A) and FL (C) with the same size II are 35 cm while FL (B) sized II is 23 cm. The results of the tipical dose rate test for FL (A), FL (B), and FL (C) are 11.428 mGy/minute, 11.712 mGy/minute and 12.518 mGy/minute, respectively. All results of the testing of the typical ESD dose rate are still within the test passes which are ⩽17 mGy/minute as required by BAPETAN Regulation No. 2 in 2018. The value of the maximum dose rate in air of each planes is very varied from the maximum value on FL (B) is 11.402 mGy/minutes, while the minimum value occur to FL (C) is 4.311 mGy/minutes. As for FL (A), the maximum dose rate in air is 7.998 mGy/minutes. All results of testing the maximum dose rate in air are still below the test pass value required by BAPETAN which is 50 mGy/minutes. The value of the dose rate of surface II varies greatly from FL (B) having a maximum value is 68.2 µGy/m inutes while FL (A) and FL (C) are 33.3 µGy/minutes and 2.4 µGy/minutes, resvectively. All results of testing the dose rate of the surface of Image Intensifier (II) are still below the test pass value required by BAPETAN which is 60 µGy/minute for size II 23 cm and 90 µGy/minute for size II ⩾ 23 cm.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Reference12 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3