Author:
Lin Jinwei,Wang Dongsheng,Zhang Le,Ji Tao,Wang Hui
Abstract
Abstract
Due to the constant power loads (CPLs), the system damping of the DC microgrid is reduced, which will lead to the collapse of bus voltage. In addition, the errors of current sharing amplify due to different line impedances. To address these issues, a hybrid coordination control strategy is proposed for parallel-connected boost converters, which realizes stable control and maintains the accuracy of the current distribution. Firstly, a passivity-based control (PBC) with a proportional-integral (PI) regulator is developed. The virtual damping-based PBC enhances the system damping and the PI regulator eliminates errors. On this basis, a secondary voltage control (SVC) featuring simplicity and weak dependence on communication is introduced to remove the errors of current distribution. Finally, the hybrid coordination control strategy is verified by RT-LAB-based hardware in the loop (HIL) experiment.
Reference10 articles.
1. Constant power loads and their effects in DC distributed power systems: A review;Suresh;Renewable & Sustainable Energy Reviews,2017
2. A Novel Composite Nonlinear Controller for Stabilization of Constant Power Load in DC Microgrid;Xu;IEEE Transactions on Smart Grid,2019
3. Review on Advanced Control Technologies for Bidirectional DC/DC Converters in DC Microgrids;Xu;IEEE Journal of Emerging and Selected Topics in Power Electronics,2021
4. A review of transient stability analysis of power systems with power electronics;Zhu;Chinese Journal of Electrical Engineering,2017
5. Passive control method for DC/DC switching converters;Wu;Journal of Electrical Engineering Technology,2004