Author:
Budiman Priatna Ahmad,Tresnawati Teni,Alamsyah Ahmad Tossin,Riandini
Abstract
Abstract
Authentication and Identification is primary part of biometric technology. Currently, electrocardiogram (ECG) is not only being used as a diagnostic tool for clinical purposes, but also as a new biometric tool for high level security system because of its liveliness and uniqueness that is hard to imitate and manipulate. There are many fiducial (signal mark) that is classified from ECG morphology (QRS Complex, P, T waves) has already been researched for this purpose. For non fiducial, many researches are focus on dynamic character from heartbeat (ECG Signal). Heart Rate Variability (HRV) analysis is part of non fiducial classifier. This paper reviews Heart Rate Variability analysis (time and frequency domain) as part of multi matches, one of scenario from multimodal biometric. Sample of person’s heartbeat signal is taken from ECG Database MIT-BIH (MIT and Harvard) and the result of every parameter will be analyzed by Biometric Performance Standards Tools (ISO/IEC IS 19795-1) such as: False Non-Match Rate (FNMR), False Match Rate (FMR) and Thresholds EER (Equal Error Rate). Analysis should show accuracy of multi matches Heart Rate Variability (HRV). As integrator tool, LabView is used to collect offline ECG, process the data and generate HRV Analysis.
Subject
General Physics and Astronomy
Reference37 articles.
1. Environmental Testing Methodology in Biometrics;Saavedra,2010
2. Biometric Cryptosystems: for User Authentication;Shobha;Int. J. Innov. Res. Comput. Commun.Eng.,2015
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献