Abstract
In this paper, a fractured and corroded tubing string was analyzed through macroscopic observation, chemical composition analysis, metallographic and mechanical test. The corrosion products were studied by SEM, EDS, and XRD method. The results showed that the corrosion of tubing in this well was caused by CO2 corrosion, the well contains CO2 medium and increasing water cut in the late stage of development were the main reasons of serious corrosion, the scaling on the tubing wall aggravated the corrosion. Finally, some suggestions were proposed for avoiding or slowdown this kind of corrosion failures.
Subject
Computer Science Applications,History,Education
Reference14 articles.
1. Failure analysis of P110 steel tubing in low-temperature annular environment of CO2 flooding wells;Liu;Engineering Failure Analysis
2. Stress corrosion crack evaluation of super 13Cr tubing in high temperature and high-pressure gas wells;Zhi;Engineering Failure Analysis
3. Analysis of the corrosion and fracture of P110S tubing in a well of Tahe oilfield;Xinyong;Materials protection
4. Failure analysis of corrosion and fracture of P110 Steel tubing in a condensate well in west China;Jiangjiang;Materials protection
5. Failure analysis of P110 tubing string in the ultra-deep oil well[J];Zhu;Engineering Failure Analysis,2011