Calibration of whole body counter for assessment of internal dose in the human body

Author:

Dararutana C,Abdullah N

Abstract

Abstract In the Malaysian Nuclear Agency (Nuklear Malaysia), the ORTEC Whole Body Counter System, bed type was used for assessing internal dose due to intake of gamma radionuclides in the human body. In this study, the performance of ORTEC Whole Body Counter System includes energy calibration, counting efficiency, validation test and minimum detectable activity (MDA) for the radionuclides of interest (ROI) has been investigated using ORTEC whole body counter phantom and mixed standard sources having gamma energies between 59.5 keV and 1836.2 keV. Later, the whole body counting was performed to determine the existence of any gamma radionuclides in the body. The result of the energy calibration was within the tolerance limit of ± 5%. The counting efficiency varies between 0.0000881 cps/Bq and 0.000332 cps/Bq. The results of the validation test show that the bias (Br) and repeatability (SBr) are within the acceptable range of -0.25 ≤ Br ≤ +0.50 and SBr ≤ 0.40, respectively. The MDA for each ROI of I-131, Cs-137 and Co-60 were 165.4 ± 10.0 Bq, 144.6 ± 11.5 Bq and 167.3 ± 30.5 Bq, respectively. A total of 14 volunteers from Postgraduate Educational Course in Radiation Protection and Safety of Radioactive Sources (PGEC-16) were invited to perform the whole body counting. Each volunteer was scanned for 1200 s with the bed speed of 0.065 inch/s. The results show that there is no internal exposure found for all monitored person. Consequently, it can be concluded that the ORTEC Whole Body Counter System (WBC) is now ready to be used for internal dose assessment.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Reference7 articles.

1. Quality control procedures for a whole-body counter;McCormick;J. Nucl. Med. Technol.,1975

2. Whole-body counting of Fukushima residents after the TEPCO Fukushima Daiichi nuclear power station accident;Momose,2012

3. An intercomparison of counting efficiency and the performance of two whole-body counters according to the type of phantom;Pak;J. Radiol. Prot. Res.,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3