Comparative trace copper and iron analysis of unused and running transformer oil is performed by iCP-MS with pretreatment by ashing, acid dissolution and direct injection method. The advantages and drawbacks of each of the listed methods are discussed. The direct injection method is so simple and time-consuming that can realize accurate determination of copper in oil, while it is not suitable for determination of iron in used transformer oil. Although limited by availability of equipment, acid dissolution method has good accuracy and reproducibility for the determination of transformer oil in all states.
Subject
General Physics and Astronomy
Reference6 articles.
1. Copper particle contamination detection of oil-immersed transformer using laser-induced breakdown spectroscopy[J];Ye;Spectrochimica Acta Part B: Atomic Spectroscopy
2. Spectrophotometric assay for copper and iron in transformer oil using partial least squares regression (PLS2)[J];Rodriguez;Dielectrics & Electrical Insulation IEEE Transactions on,2006
3. Determination of Iron, Copper, Lead, Tin, Arsenic, Silver, Chromium, Nickel and Vanadium in Oil by Inductively Coupled Plasma Mass Spectrometry[J];Cheng,2011
4. Investigation by ICP-MS of trace element levels in vegetable edible oils produced in Spain[J];Llorent-Martínez;Food Chemistry,2011
5. Trace metal analysis in petroleum products: Sample introduction evaluation in ICP-OES and comparison with an ICP-MS approach[J];Lienemann;Oil & Gas Science and Technology - Revue de l\"IFP,2007