Author:
Wang Wenbing,Wang Xutong,Chen Yinhui,Sun Beiyun
Abstract
Abstract
The shielding efficiency of coaxial cable is characterized by its anti-interference ability in electromagnetic environment. The testing methods include three-axis method, GTEM chamber method, line injection method, power absorption clamp method, reverberation chamber method and so on. In practical application, it is found that the shielding performance of the cable under high altitude electromagnetic pulse (HEMP) does not accord with the shielding efficiency measured by the cable. While a typical multi-layer shielded cable is selected as the test object, a test method is designed and tested under electromagnetic simulator, and then the test results are verified and extended by CST simulation. Finally, the reason of this phenomenon is analysed theoretically, which has important reference significance for the prediction and testing of shielding efficiency of cable in HEMP environment.
Subject
General Physics and Astronomy
Reference10 articles.
1. Effect of wiring method on coupling of cables under HEMP irradiation [J];Pei;Earth and Environmental Science,2018
2. Coupling effect of high power electromagnetic environments with different bandwidths on overhead cables [J];Xin;Chinese Journal of Radio Science,2013
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献